Difference between revisions of "Technology Transfer"

From FirePRA
Jump to navigation Jump to search
Line 1: Line 1:
−
gsifjdsklfjds
+
EPRI and NRC-RES periodically publish the material from the jointly held EPRI/NRC-RES Fire PRA Training. This annual training covers the main technical topics of developing a fire PRA.
  
 
[https://www.epri.com/#/pages/product/000000003002005206/?lang=en-US EPRI 3002005206] documents the slides presented in the 2016 EPRI/NRC Fire PRA Training Course. The five modules covered in this report include:
 
[https://www.epri.com/#/pages/product/000000003002005206/?lang=en-US EPRI 3002005206] documents the slides presented in the 2016 EPRI/NRC Fire PRA Training Course. The five modules covered in this report include:
Line 14: Line 14:
 
*[https://www.nrc.gov/reading-rm/doc-collections/nuregs/conference/cp0303/v4/ Fire HRA]
 
*[https://www.nrc.gov/reading-rm/doc-collections/nuregs/conference/cp0303/v4/ Fire HRA]
 
*[https://www.nrc.gov/reading-rm/doc-collections/nuregs/conference/cp0303/v5/ Advanced Fire Modeling]
 
*[https://www.nrc.gov/reading-rm/doc-collections/nuregs/conference/cp0303/v5/ Advanced Fire Modeling]
−
 
  
 
[https://www.epri.com/#/pages/product/000000003002000267/?lang=en-US EPRI 3002000267] This report documents the course prerequisites and Fire HRA course from the 2010 EPRI/NRC-RES Fire PRA Training. Similar to EPRI 3002005205, the slides can be viewed via the links below, but the recordings of the training must be ordered.  
 
[https://www.epri.com/#/pages/product/000000003002000267/?lang=en-US EPRI 3002000267] This report documents the course prerequisites and Fire HRA course from the 2010 EPRI/NRC-RES Fire PRA Training. Similar to EPRI 3002005205, the slides can be viewed via the links below, but the recordings of the training must be ordered.  
 
*[https://www.nrc.gov/reading-rm/doc-collections/nuregs/conference/cp0301/v1/ Volume 1] covers the basic concepts of circuit analysis, fire analysis, fire HRA, and PRA
 
*[https://www.nrc.gov/reading-rm/doc-collections/nuregs/conference/cp0301/v1/ Volume 1] covers the basic concepts of circuit analysis, fire analysis, fire HRA, and PRA
 
*[https://www.nrc.gov/reading-rm/doc-collections/nuregs/conference/cp0301/v2/ Volume 2] covers the initial offering of the Fire HRA course.
 
*[https://www.nrc.gov/reading-rm/doc-collections/nuregs/conference/cp0301/v2/ Volume 2] covers the initial offering of the Fire HRA course.

Revision as of 16:53, 13 November 2018

EPRI and NRC-RES periodically publish the material from the jointly held EPRI/NRC-RES Fire PRA Training. This annual training covers the main technical topics of developing a fire PRA.

EPRI 3002005206 documents the slides presented in the 2016 EPRI/NRC Fire PRA Training Course. The five modules covered in this report include:

  • Fire PRA
  • Electrical Analysis
  • Fire Analysis
  • Fire Human Reliability Analysis (HRA)
  • Advanced Fire Modeling

EPRI 3002005205 This report documents both sessions of the 2012 EPRI/NRC-RES Fire PRA Training. This report includes the slides and handouts in each module as well as video recordings of the training. The slides from the training are accessible via the links below. To obtain the recordings please contact the EPRI Order Center at 1-800-313-3774 Option 2 or 650-855-2121. You may also send an email to orders@epri.com or EPRI members can log in and use the Order Request Form.

EPRI 3002000267 This report documents the course prerequisites and Fire HRA course from the 2010 EPRI/NRC-RES Fire PRA Training. Similar to EPRI 3002005205, the slides can be viewed via the links below, but the recordings of the training must be ordered.

  • Volume 1 covers the basic concepts of circuit analysis, fire analysis, fire HRA, and PRA
  • Volume 2 covers the initial offering of the Fire HRA course.